SS OCT Angio, OCT Angiography



Kort beskrivelse

OCT Angiography using Swept Source OCT: superior imaging through a powerful combination of technologies Læs mere>

Nøglefunktioner

  • High-sensitivity imaging and deeper intravascular flow visualization
  • Rapid scanning, real time eye tracking
  • The OCTARA difference

Relaterede produkter




Beskrivelse

OCT Angiography using Swept Source OCT: superior imaging through a powerful combination of technologies
Topcon's SS OCT Angio is the only system that combines high-quality OCT angiography with a Swept Source OCT. Built on the clinically proven DRI OCT Triton platform, it is powered by OCTARA™, a proprietary image processing algorithm that provides highly sensitive angiographic detection. The exceptional visualization of vascular structures, even in the choroid and deeper retinal layers is realized.

High-sensitivity imaging and deeper intravascular flow visualization
Swept Source  technology and OCTARA™ allow  the deeper structures to be visualized with less depth- dependent signal roll-off, and detect even low microvascular flow with high sensitivity. Additionally, the 1μm wavelength makes OCT imaging possible for patients with media  opacities.

Rapid scanning, real time eye tracking
At 100,000 A scans per second coupled with the SMARTtrack eye tracking system, the Topcon DRI OCT Triton quickly completes the OCT Angiograph* scan and provides a clear image  of the retinal microvascular flow network.

Enhanced diagnostic efficiency & workflow integration
Multimodal platform provides easy, yet comprehensive comparison of microvascular impairment with Fluorescein Angiography (FA), Fundus Auto Fluoresence (FAF), OCT and color fundus images  in a single device. DRI OCT Triton Plus has FA and FAF as factory option.

The OCTARA™ difference
OCTARA is the image processing technology which extracts the signal changes derived from vascular flow using multiple OCT B scans acquired at the same position. It demonstrates high sensitivity for the detection of low blood flow in microvasculature. It is anticipated that OCTARA will be useful for detecting microaneurysms or capillary abnormalities. using multiple OCT B scans acquired at the same position. It demonstrates high sensitivity for the detection of low blood flow in microvasculature. It is anticipated that OCTARA will be useful for detecting microaneurysms or capillary abnormalities.

Accurate tracking system
SMARTTrack™, incorporated in the DRI OCT Triton, has been further developed for OCT Angiography. It now detects eye movements and blinks instantaneously and modifies the scan position to ensure complete scanning of all areas

Multimodal Viewing & Reporting
Angiography images, high-quality B scans and fundus photography can all be viewed on an single screen using IMAGEnet 6, so the area of interest can be assessed using multiple image  modalities. Selected layers can easily be customized to enhance the clarity of specific pathological features

 

 